A. No. Requirement 7 addresses the requirement for usable kitchens and bathrooms so that a person in a wheelchair can maneuver about the space. The legislative history of the Fair...
Search Results "Hand-Held Shower Unit"
Commonly Searched Documents
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
-
27.1 Q. Do the Guidelines set any requirements for the type or location of bathtub controls?
A. No, except where the specifications in Requirement 7(2)(b) are used. In that case, while the type of control is not specified, the control must be located as shown in Figure 8 of...
-
In-swinging Bathroom Doors
Comment. One commenter stated that in-swinging bathroom doors generally are problematic, unless the bathroom is unusually large. The commenter noted that an in-swinging door makes it...
-
§100.205(c)(3)(ii)
(ii) Light switches, electrical outlets, thermostats, and other environmental controls in accessible locations;
-
1.1 Q. Are townhouses in non-elevator buildings which have individual exterior entrances required to be accessible?
A. Yes, if they are single-story townhouses. If they are multistory townhouses, accessibility is not required. (See the discussion of townhouses in the preamble to the Guidelines...
-
9.2.1 General
Units, sleeping rooms, and suites required to be accessible by 9.1 shall comply with 9.2....
-
206.2.3 Multi-Story Buildings (Exception 4), F206.2.3 Multi-Story Buildings (Exception 4)
In facilities with residential dwelling units, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with...
-
Re: Section 307 Protruding Objects
Could you please direct me to the section in the code indicates that an 8" deep shelf at 40"-48" AFF is code compliant as stated? Thank you in advance!
-
Re: Section 307 Protruding Objects
Hi Justin, Sorry I didn't see you question sooner. See ADAS 603.4 and CBC 11B-603.4. The (maximum) depth of a shelf isn't noted, but you're unlikely to find many shelves less...
-
233 Residential Facilities, F233 Residential Facilities
by Occupant of Unit 233.3.1.2.2 Group Sites 233.3.1.2.2.1 Unit Pads 233.3.1.2.2.2 Units Installed 233.3.1.2 Residential Dwelling Units with Communication Features...
-
11B-708.4.2 Residential dwelling unit interface
The residential dwelling unit system interface shall include a telephone jack capable of supporting voice and TTY communication with the common use or public use system interface....
-
11B-708.4.2 Residential dwelling unit interface
The residential dwelling unit system interface shall include a telephone jack capable of supporting voice and TTY communication with the common use or public use system interface....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
(3) Doors within individual dwelling units
The final Guidelines recommend that doors intended for user passage within individual dwelling units have a clear opening of at least 32 inches nominal width when the door is open 90 degrees...
-
The Basis for the 2010 ADA Standards Pocket Guide
Learn the basis of the 2010 ADA Standards Pocket Guide
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
F206.5.3 Transient Lodging Facilities
EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3....
-
206.5.3 Transient Lodging Facilities
EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....