Where the distance from the wheelchair to the clothes rod or shelf exceeds 10 in (255 mm) (as in closets without accessible doors) the height and depth to the rod or shelf shall comply with...
Search Results "Adjustable Height Counter"
-
4.25.3 Height
-
Guest Rooms
Bed heights for accessible rooms should be between 17-23 inches above the floor Do not have border frame which prevents the wheelchair from being directly next to the mattress....
-
A4.31.3 Mounting Height
The operator button is located at a height of 46 in (1170 mm) if the coin slot of the telephone is at 54 in (1370 mm)....
-
A4.31.3 MOUNTING HEIGHT
The operator button is located at a height of 46 in (1170 mm) if the coin slot of the telephone is at 54 in (1370 mm)....
-
407.12 Reach Height
At least one of each type of operable part of stationary ICT shall be at a height conforming to 407.12.2 or 407.12.3 according to its position established in 407.12.1 for a side reach or...
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
11B-704.4.1 Height
Advisory 11B-704.4.1 Height....
-
5.8.3.1 Breast Platform Height
5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
5.8.2.5 Toe Height Recommendation
recommended that the toe height be set to 18 inches (when the breast platform is at the 34 inch height discussed above)....
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
We believe the addition of the adjustability requirement delivers by far a larger increase in access than having a single minimum height of 17 inches....
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. ...
-
SEAT HEIGHT MEASUREMENT DETAIL
SEAT HEIGHT MEASUREMENT DETAIL Regardless of measurement technique used, the height is measured at the highest point of the seat, inclusive of bolsters, with the foam in an uncompressed...
- Bradley Adjustable Tilt Mirror 782
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
M303.2.4.2.2 Height
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
Protocol C Heights Obtained
For the maximum height transfers HERL's percentile heights were slightly higher for the 25th and 75th percentiles than the NDVWSC heights....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...