These underlying provisions tell entities the end they must achieve; the reasonable modification provision tells entities how to achieve that end in situations in which normal policies and...
Search Results "Head End Wall"
Commonly Searched Documents
-
B.
-
5. Toilet centerline
Toilet centerline: The toilet bowl needs to be centered 18 inches from the side wall, so that inmates with disabilities can use the side grab bar....
-
11B-604.8.2.3 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
- Bradley Standard Series Napkin Disposal
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing a wheelchair space and permitting pass-through from one end to the other, the length of the gripping surface on horizontal standing supports shall be at...
-
T505.3 Location of Operable Parts
Operable parts shall be located adjacent to the toe end of the clear space or shall be located no more than 10 inches (255 mm) measured from the centerline of the long dimension of the clear...
-
Running Slope
In other words, the slope is the difference in elevation from the beginning to the end of a part of a trail, outdoor recreation access route, or beach access route, measured in the direction...
-
Title and label placement
However, it was at the bottom of the map and most people either missed it or didn’t find it until the end of their exploration....
-
I. BACKGROUND
at the northern end....
- Pressalit Care Adult changing table 3000, electrically height adjustable
-
Rear Grab Bar
The proposed rule specified that the rear grab bar be 24 inches long minimum, centered on the water closet, or at least 36 inches long "where wall space permits" (604.5.2)....
-
11B-903.4 Back support
The bench shall provide for back support or shall be affixed to a wall along its long dimension....
-
1136A.1 Receptacle heights
Physical barriers and obstructions shall not extend more than 25 inches (635 mm) from the wall beneath the receptacle....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
-
704.6 Structural stability
The wall shall extend to the height required by Section 704.11 and shall have sufficient structural stability such that it will remain in place for the duration of time indicated by the...
-
609.5 Surface Hazards
Grab bars and any wall or other surfaces adjacent to grab bars shall be free of sharp or abrasive elements and shall have rounded edges....
-
4.34.6.4(2)
The finished floor shall extend under the counter to the wall....
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Keep wall surfaces above handrails free of any protrusions....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-608.10 Soap dish
Where a soap dish is provided, it shall be located on the control wall at 40 inches (1016 mm) maximum above the shower floor, and within the reach limits from the seat....
- Stanley QRM 100 Series Grade 1 Extra Heavy Duty Exit Devices
-
Common Problems with Signs
Common Problems with Signs Ø Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to the...