Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
Search Results "Barrier Wall"
Commonly Searched Documents
-
11B-604.8.1.1 Size
-
Limiting Factor
An extreme, uncorrectable environmental barrier that makes the trail beyond the barrier unreachable for many people with mobility limitations....
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
Grab Bars
Grab bars are required on one side wall and the rear wall....
-
H1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch?...
-
4.30.6 Mounting Location and Height
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
711.3.2 Membrane penetrations
Where walls and partitions are required to have a minimum 1-hour fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced....
-
Maneuvering Clearances at Doors [4.13.6]
Clearance to the wall plane next to the door (even when the door is in a recess) is essential....
-
Limiting Factor
Limiting Factor—An extreme, uncorrectable environmental barrier that makes the trail beyond the barrier unreachable for people with mobility limitations....
-
68.10(1) Act
(1) Act--Texas Government Code, Chapter 469, Elimination of Architectural Barriers (the Texas Architectural Barriers Act)....
-
1018.10 Dune Crossings
This section requires handrails complying with 505 of the Architectural Barriers Act Accessibility Guidelines and curbs or barriers to be provided where the slope of a beach access route...
-
Temporary and Permanent Structures: ADA Standard Section 201.3
Section 201.3 covers the application of the most current requirements for temporary and permanent structures.
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
11B-407.4.10 Support rail
Support rails shall be provided on at least one wall of the car. Advisory 11B-407.4.10 Support rail....
-
3.2 Why Is a Reasonable Accommodation Necessary?
The ADA recognizes that such barriers may discriminate against qualified people with disabilities just as much as overt exclusionary practices....
-
704.8 Allowable area of openings
Values given are percentage of the area of the exterior wall. b....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
4.3.5.2 180-degree turn
Our research findings for this turn apply to corridors and other circulation spaces are bounded by two parallel walls or three walls....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 180-degree Turn
These data are based on measurements of wheeled mobility users performing 180-degree turns in a dead-end hallway, built with mock walls....