Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
Search Results "Barrier Wall"
Commonly Searched Documents
-
608.5.2 Standard Roll-In Type Shower Compartments
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
- Bobrick Koala Kare Horizontal, Stainless Steel Wall Mounted Baby Changing Station KB110-SSWM
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
11B-812.5.3 Relationship to accessible routes
A curb, wheel stop, bollards, or other barrier shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....
-
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Clearance: ADA Standard Section 804.2
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. [ECTCR UFAS 4.34.5.2(3)] EXCEPTIONS: 1....
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
1134A.7, Item 1
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Dual grab bars on the back wall are needed for transfer to the seat and into the tub....
- DORMA ED700 Low-Energy Swing Door Operator
-
4. ABSOLUTE DIMENSIONS