Delta® toilets with FlushIQ™ Technology are smart toilets that feature the latest technologies from Delta Faucet: a touch-free flush, overflow protection and leak detection....
Search Results "Toilet Compartment"
Commonly Searched Documents
- Delta Toilet with FlushIQ Technology
- Bobrick Two-Wall Toilet Compartment Grab Bar B-5897
- Bobrick Two-Wall Toilet Compartment Grab Bar B-6897
- Access Board: Tactile Sign Location
- Access Board: Tactile Sign Height
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
608.2.2 Standard Roll-In Type Shower Compartments
608.2.2 Standard Roll-In Type Shower Compartments....
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
608.3.3 Alternate Roll-In Type Shower Compartments
608.3.3 Alternate Roll-In Type Shower Compartments....
-
608.5.2 Standard Roll-In Type Shower Compartments
608.5.2 Standard Roll-In Type Shower Compartments....
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
- Disability Access - Tips for the small business
-
F216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior...
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of permanent interior...
-
703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
216.2 Designations
216.2 Designations. Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of...
-
703.5.2 Case
703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both.
-
A4.30.3 COLOR CONTRAST
The greatest readability is usually achieved through the use of light-colored characters or symbols on a dark background.
-
4.1.3(16)(a)
(a) Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6.