The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
Search Results "Character Height (Raised)"
Commonly Searched Documents
-
M301.4.1 Clearance in Base
-
Handrails [§504.6, §505]
Handrails [§504.6, §505] Handrails are required on both sides of stairs and must be continuous within the full length of each stair flight. Inside handrails on switchback or...
-
1009.5.3 Height
1009.5.3 Height. The height of the transfer platform shall comply with 1009.4.2....
-
11B-411.2.3.1 Floor designation signs
Signs shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
- Brewer Access™ High-Low Exam Table
-
Car Controls [§407.4.6 and §407.4.7]
Car Controls [§407.4.6 and §407.4.7] If more than one car control panel is provided in a car, both must comply (except in existing cars where only 1 panel must comply). Car...
- Access Board: Exit Signs
-
COSTS TO LOWER MINIMUM TABLE HEIGHT
COSTS TO LOWER MINIMUM TABLE HEIGHT To be useful for its intended purpose, examination tables and chairs must maintain a high height of at least 32 inches, so that the health care provider...
-
Threshold Height
Section 404.2.5 addresses the height of thresholds....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
1008.3.1.2 Height
1008.3.1.2 Height....
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower....
-
704.4.1 Height
704.4.1 Height. When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
A. Question 1: Applicability of Section 904.4.1’s Exception
In other words, an entity satisfies Section 904.4.1 whenever it provides a sales or service counter that is of a uniform height of less than 36 inches. See generally id....
-
5.7.1 Lift Compatibility Clearance in Base for M301
Description: For portable floor lifts to be effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
Height [4.27.3]
Height [4.27.3] The operable portions of controls and operating mechanisms must be within established reach ranges for either a forward or side reach as required in 4.2.5 and 4.2.6 (see...
-
Technical Memorandum TM 2013-19 Private Toilet and Bathing Rooms
Lavatories and Sinks 606.2, Exception 2: Clear Floor Space 606.3, Exception 1: Height. Bathtubs 607.4, Exception 1: Grab Bars....
-
Eye Height
Table 7 shows that the mean eye height for bicyclists in this study was 157 cm (62 inches). The 85th percentile eye height for bicyclists was 150 cm (59 inches)....
-
611.4 Height
611.4 Height. Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
704.4.1 Height
Advisory 704.4.1 Height....
-
704.4.1 Height
Advisory 704.4.1 Height....