Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
Search Results "Submerged Depth"
Commonly Searched Documents
-
Side Approach
-
Side Approach
Side Approach Side reach depth is important to consider in the design and location of sinks....
-
Side Approach
In June 1993, additional specifications were provided for the maximum height based on the reach depth....
-
308 Reach Ranges
Accessible reach ranges are specified according to the approach (forward or side) and the depth of reach over any obstruction....
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-308.3.1 Unobstructed
Exceptions: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum....
-
Depth: ADA Standard Section 703.2.1
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background.
-
Depth: ADA Standard Section 802.1.3
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where a wheelchair space can be entered only from the...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
4.25.3 Height
Where the distance from the wheelchair to the clothes rod or shelf exceeds 10 in (255 mm) (as in closets without accessible doors) the height and depth to the rod or shelf shall comply with...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets...
-
Knee and Toe Space
The knee and toe space must be at least as deep as the reach depth measured from the leading edge of the obstruction....
-
Forward Reach [4.2.5]
Since the forward reach over an obstruction is limited by how far a person using a wheelchair can pull up below it, the depth of reach cannot exceed the amount of usable clear floor space...
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
308.3.2 Obstructed High Reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth...
-
308.3.2 Obstructed High Reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth...
-
11B-308.3.2 Obstructed high reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum and the depth...
-
11B-308.3.2 Obstructed high reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum and the depth...
-
308.3.2 Obstructed High Reach
floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum and the depth...