Plan 2B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
Search Results "Shower Room"
Commonly Searched Documents
-
Plan 2B: 13-Foot Wide Accessible Guest Room
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.2 Standard roll-in type shower compartments
(991 mm) to 41 inches (1041 mm) above the shower floor....
-
11B-608.5.2 Standard roll-in type shower compartments
11B-608.5.2 Standard roll-in type shower compartments....
-
608.8 Shower Enclosures
608.8 Shower Enclosures. Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-608.4 Seats
A folding seat shall be provided in roll-in type showers. Seats shall comply with Section 11B-610. [2010 ADAS] 608.4 Seats. ...
-
11B-608.4 Seats
A folding seat shall be provided in roll-in type showers. Seats shall comply with Section 11B-610. [2010 ADAS] 608.4 Seats....
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. [ECTCR UFAS 4.21.8, 4.34.5.6]...
-
8. Shower Curbs
Are the roll-in showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Plan 5B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
608.5.1 Transfer Type Shower Compartments
608.5.1 Transfer Type Shower Compartments....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
4.21.8 Shower Enclosures
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
4.21.8 SHOWER ENCLOSURES
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
4.21.8 Shower Enclosures
4.21.8 Shower Enclosures. None of the respondents indicated that there were any variations from ADAAG regarding the shower enclosure....
-
608.3.2 Standard Roll-In Type Shower Compartments
608.3.2 Standard Roll-In Type Shower Compartments....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
11B-213.2 Toilet rooms and bathing rooms
Where toilet rooms are provided, each toilet room shall comply with Section 11B-603. Where bathing rooms are provided, each bathing room shall comply with Section 11B-603....
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...