Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
Search Results "Shower Room"
-
11B-608.9 Shower floor or ground surface
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4....
-
F224.2 Guest Rooms with Mobility Features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table F224.2....
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
224.2 Guest Rooms with Mobility Features
Facilities on a common site that each have 50 or fewer guest rooms may be combined for the purposes of determining the required number of accessible rooms and type of accessible bathing...
-
224.2 Guest Rooms with Mobility Features
224.2 Guest Rooms with Mobility Features. In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2....
-
Shower Compartments
Shower Compartments....
-
4.23.1 Minimum Number
Bathrooms, bathing facilities, or shower rooms required to be accessible by 4.1 shall comply with 4.23 and shall be on an accessible route....
-
General: ADA Standard Section 608.1
Section 608.1 of the ADA Standards covers information in the current ADA Standards for shower compartments.
-
1607.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
4.23.1 MINIMUM NUMBER
Bathrooms, bathing facilities, or shower rooms required to be accessible by 4.1 shall comply with 4.23 and shall be on an accessible route....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
1607A.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
Toilet and Bathing Rooms: ADA Standard Section 805.4
Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1607.9.2 Grab bars, shower seats and accessible benches
[DSA-AC & HCD 1-AC] See Chapter 11A, Section 1127A.4, and Chapter 11B, Sections 11B-609.8, 11B-610.4 and 11B-903.6, for grab bars, shower seats and dressing room bench seats, as applicable...
-
11B-224.2 Guest rooms with mobility features
NUMBER OF REQUIRED ROOMS WITH ROLL-IN SHOWERS 2 TOTAL NUMBER OF REQUIRED ROOMS 1 1 0 1 2 to 25 1 1 [2010 ADA Standards...
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....