Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
Search Results "Ramp"
-
1015.2 Where required
-
1015.3 Height
On ramps and ramped aisles, from the ramp surface at the guard....
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
1132A.4, Item 4
or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp...
-
Components: ADA Standard Section 402.2
Section 402.2 covers the current ADA Standards for components of an accessible routes.
-
1009.2 Continuity and components
Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable. Areas of refuge complying with Section 1009.6....
-
1009.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1012....
-
Ramps: ADA Standard Section 405
Section 405 covers the current ADA Standards for ramps.
-
SECTION 1012 RAMPS
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
General: ADA Standard Section 405.1
Section 405.1 of the ADA Standards covers information in the current ADA Standards for ramps.
-
Cross Slope: ADA Standard Section 405.3
Section 405.3 covers the current ADA Standards for cross slope requirements on ramps.
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured...
-
1015.3 Height
On ramps and ramped aisles, from the ramp surface at the guard....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-405 Ramps