1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
Search Results "Ramp"
-
1007.2 Continuity and components
-
1007.2, Item 8
Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
1007.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1010....
-
SECTION 1010 RAMPS
SECTION 1010 RAMPS [DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is...
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1013.3 Height
On ramps, from the ramp surface at the guard. Exceptions: 1. ...
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
1132A.4, Item 4
or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp...
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-405 RAMPS
-
11B-405.1 General
Ramps on accessible routes shall comply with Section 11B-405....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. [2010 ADAS] Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
- Access Board: Changes in Level
- Accessible Pittsburgh: The One Step Project
- All Access, Inc. ADA Platforms
- Amramp Modular Ramps
- Amramp Portable Ramps
- Boost Your Business - Chapter 4 - Ramps
- Design Guidelines for the Visual Environment
- Disability Access - Tips for the small business
- EZ-ACCESS GATEWAY™ Solid Surface Portable Ramp
- EZ-ACCESS Suitcase Singlefold AS Ramp