Present PL ADA lever latch held together with retaining ring
Search Results "Partition"
Commonly Searched Documents
- General Partitions ADA Lever Latch (2000F-PL)
- Jacknob Corp. 6150 ADA Partition Door Hardware
- Jacknob Corp. 2610 ADA "K" Partition Hardware
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
- Jacknob Corp. 163500 ADA Concealed Latch Partition Hardware
- Jacknob Corp. 122910 ADA Concealed Latch Partition Hardware
- General Partitions ADA Door Pull Kit (6300HC-SS)
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
ALTERATION
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height partitions...
-
Compartment Doors
The proposed rule specified the location of doors in the front partition, which were required to be hinged 4 inches from the side wall or partition farthest from the water closet (604.8.1.2...
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....