Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
Search Results "Forward Approach"
-
Clear Floor Space: ADA Standard Section 602.2
-
Knee and Toe Space
If the forward reach to operable parts extends over an obstruction, such as a counter, clearances for toes and knees is required below....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
I1b
For a front approach (where clear floor space at least 30 inches wide x 48 inches long), is the coin slot no higher than 48 inches above the floor?...
-
4.31.2 Clear Floor or Ground Space
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
4.24.3 Knee Clearance
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks.
-
Clear Floor Space [4.19.3]
Clear Floor Space [4.19.3] Clear floor space should be centered at the fixture (although this is not specifically required by ADAAG). Additional width is required where the clear...
-
4.24.3 KNEE CLEARANCE
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks.
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view the information shown in Fig. 4, 5, and...
-
A4.2.5 & A4.2.6 REACH
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a). These drawings approximate in the plan view information shown in Fig. 4, 5, and 6 in other...
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach....
- Access Board: Forward Approach at an Alcove
-
Forward Approach
For wheelchair access, the proposed rule required a forward approach at cantilevered units but allowed a parallel approach at other types of units, such as those that are floor mounted....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....