These data depict the reaching abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction...
Search Results "Forward Approach"
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach...
-
407.8.1.2 Vertical Plane for Forward Reach
Where a forward reach is provided, the vertical reference plane shall be 30 inches (760 mm) long minimum....
-
407.12.1.2 Vertical Plane for Forward Reach
Where a forward reach is provided, the vertical reference plane shall be 30 inches (760 mm) long minimum. Figure 407.12.1...
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- McGuire Manufacturing Co., Inc. 155CRSWC: Offset Lavatory Strainer with Chain and Rubber Stopper
-
407.12.3 Forward Reach (Section-by-Section Analysis)
407.12.3 Forward Reach (Section-by-Section Analysis) This section contains proposed requirements for operable parts providing either an unobstructed or obstructed forward reach....
- 309.3 Baby Changing Table Pull Down Handle Height
-
704.2.1.1 Parallel Approach
704.2.1.1 Parallel Approach....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
Example 2: Without Cooking Facilities
Forward approach required to sink even if no cooktop or conventional range is provided since 606.2, Exception 1, is applicable only to kitchen sinks and wetbars....
-
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis)
407.12.1.2 Vertical Plane for Forward Reach (Section-by-Section Analysis) This section proposes that, where a forward reach is provided, the vertical reference plane must be, at a minimum...
-
604.8.1.3 Approach
604.8.1.3 Approach. Compartments shall be arranged for left-hand or right-hand approach to the water closet....
-
4.1.3 Wheelchair Seating Space
Clear floor or ground space that is at least 30 inches by 48 inches shall be provided at each seating space that is required to be accessible and positioned for a forward approach to the...
-
704.2.1.1 Parallel Approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (255 mm) maximum....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
11B-704.2.1.1 Parallel approach
11B-704.2.1.1 Parallel approach....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....