- Figure 305.5 Position of Clear Floor or Ground Space – Drawing from the U.S. Access Board
- Figure 404.2.4.1(a) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Pull Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
-
4.31.3* Mounting Height
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
- Figure 404.2.4.1(c) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
Clear Floor Space [4.18.3]
Clear Floor Space [4.18.3] Clear floor space at least 30 inches wide is required, including between partitions where they are provided (when shields do not extend beyond the front...
-
Knee and Toe Space Depth
[See subsections ...]
-
Knee and Toe Clearance: ADA Standard Section 305.4
Section 305.4 covers the current ADA Standards for knee and toe clearance included in clear floor space.
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
Obstructed High Reach
The maximum reach of 48” is reduced to 44” when the depth of reach over an obstruction exceeds 20.” Knee and toe space must extend the full depth of reach.
-
11B-606.7 Sink depth
Where a forward approach is required at a sink, knee and toe clearance shall be provided in compliance with Section 11B-306....
-
Knee and Toe Clearance
Accessible lavatories and sinks must provide knee and toe clearance for a forward approach (606.2)....
-
4.15.5(1)
Such units shall also have a minimum clear floor space 30 in by 48 in (760 mm by 1220 mm) to allow a person in a wheelchair to approach the unit facing forward....
-
4.15.5(1)
Such units shall also have a minimum clear floor space 30 in by 48 in (760 mm by 1220 mm) to allow a person in a wheelchair to approach the unit facing forward....
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
Knee and Toe Space
If the forward reach to operable parts extends over an obstruction, such as a counter, clearances for toes and knees is required below....
-
I1b
For a front approach (where clear floor space at least 30 inches wide x 48 inches long), is the coin slot no higher than 48 inches above the floor?...
-
4.31.2 Clear Floor or Ground Space
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
11B-704.2.1.1 Parallel approach
Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
-
4.24.3 Knee Clearance
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks.