Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
Search Results "Floor Button"
-
407.2.1 Call Controls
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-
409.2 Call Buttons
409.2 Call Buttons. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309....
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
A clear floor space complying with 305 positioned for a forward approach shall be provided....
-
11B-504.8 Floor identification
Floor identification signs required by Chapter 10, Section 1023.9 complying with Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level...
-
11B-504.8 Floor identification
Floor identification signs required by Chapter 10, Section 1023.9 complying with Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level...
-
409.2 Call Buttons
Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered....
-
409.2 Call Buttons
Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension and shall comply with 309....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
Push Plates, Buttons, and Bars
Buttons that are raised or flush are easier to use than those that are recessed. (Elevator control buttons cannot be recessed, and input keys at ATM and fare machines must be raised.)...
-
Clear Floor or Ground Space: ADA Standard Section 811.2
A clear floor or ground space complying with 305 shall be provided....
-
Keypads: ADA Standard Section 407.2.1.6
Section 407.2.1.6 covers the current ADA Standards for elevator keypads.
-
Floor or Ground Surface: ADA Standard Section 802.1.1
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
Platform and Vehicle Floor Coordination: ADA Standard Section 810.5.3
Advisory 810.5.3 Platform and Vehicle Floor Coordination....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_....
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....