11B-703.7.2.7 Pedestrian traffic-control buttons....
Search Results "Floor Button"
Commonly Searched Documents
-
11B-703.7.2.7 Pedestrian traffic-control buttons
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5....
-
Operable Parts: ADA Standard Section 704.2.2
Telephones shall have push-button controls where such service is available....
-
11B-704.2.2 Operable parts
Telephones shall have push-button controls where such service is available....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
Location: ADA Standard Section 407.2.1.4
Section 407.2.1.4 covers the current ADA Standards for the location of elevator call controls.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
GROUND FLOOR
[DSA-AC] The floor of a building with a building entrance on an accessible route. A building may have one or more ground floors....
-
11B-407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction. Exception: Reserved....
-
4.10.12(2)
The call button for the main entry floor shall be designated by a raised star at the left of the floor designation (see Fig. 23(a))....
-
Clear Floor Space: ADA Standard Section 1004.1
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Clear Floor or Ground Space: ADA Standard Section 704.2.1
A clear floor or ground space complying with 305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats....
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background....
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-
407.2.1 Call Controls
Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
-