Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
Search Results "Doors in Series"
Commonly Searched Documents
-
11B-404.2.10 Door and gate surfaces
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
Rooms and Spaces: ADA Standard Section 206.5.2
Section 206.5.2 covers scoping requirements in the most current ADA Standards for accessible routes to rooms and spaces.
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates.
-
404 Doors, Doorways, and Gates
Changes made to the requirements for manually operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage...
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...
-
Is automation of doors required?
Automation of doors is not required by the Standards, but it is highly recommended for entrance doors where the opening force is significant....
-
407.3.5 Door Delay
407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
Automated Revolving Doors
Automated Revolving Doors Automated revolving doors, if large enough, may be usable by many people who use wheelchairs although ADAAG requires that a revolving door not be the only means...