There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
Search Results "Door Maneuvering Clearance"
-
1010.1.4 Floor elevation
-
6.3(5)
(5) Each bedroom shall have a door that complies with 4.13....
-
Section D: Entrances
opening (one door or one active leaf of a double door) at least 32"?...
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
Section E: Route from Entrance
. (§402.2) E8 If doors are provided along the route to the voting area, is the clear width of each door opening (one door or one active...
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
1132A.1 Primary entry doors and required exit doors
The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
1132A.5 Maneuvering clearances at doors
-
1132A.5 Maneuvering clearances at doors
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
General: ADA Standard Section 404.1
Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates....
-
Swinging Doors and Gates: ADA Standard Section 404.2.4.1
Section 404.2.4.1 covers the current ADA Standards for maneuvering clearances at swinging doors and gates....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors....
-
Recessed Doors and Gates: ADA Standard Section 404.2.4.3
Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates....
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances....
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates....
-
Doorways: ADA Standard Section 405.7.5
Section 405.7.5 covers the current ADA Standards for doorway maneuvering clearance at ramp landings....