Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
Search Results "Vertical Platform Lift"
-
11B-242.4 Spas
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm)...
-
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis) This section proposes dimensions for knee and toe space under ICT when an obstructed forward reach is provided. The...
-
9.2.2(2)
(2) An accessible route complying with 4.3 shall connect all accessible spaces and elements, including telephones, within the unit, sleeping room, or suite. This is not intended to...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
609.3 Spacing
609.3 Spacing. The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1 1/2 inches (38 mm)...
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum...
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum...
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum...
-
M301.4.1 Clearance in Base
[See subsections ...]
-
Handrail Extensions
Other specifications regarding vertical supports may be addressed in other building codes....
-
§ 36.403(e) Path of travel.
(e) Path of travel.
-
Sec.36.403(e) Path of travel
(e) Path of travel.
-
10.3.1(13)
(13) Where it is necessary to cross tracks to reach boarding platforms, the route surface shall be level and flush with the rail top at the outer edge and between rails, except for a maximum...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
M303.3 includes technical criteria for changes in level at the entry to a wheelchair space as may occur at wheelchair weight scales with raised platforms....
-
Section E: Route from Entrance
. (§ 303.4) E7 If the route to the voting area has stairs, is a platform lift or elevator provided?...
-
Transfer Systems
Transfer Systems A transfer system consists of a transfer platform and a series of transfer steps that descend into the water....
-
5.8.2.1 Height of Breast Platform at Time of Measurement
5.8.2.1 Height of Breast Platform at Time of Measurement Recommendation The Committee recommends measuring all knee and toe clearances when the top of the breast platform is set at...
-
Exception [1013.1, Exception]
When a condition for exception does not permit full compliance with a specific provision in the technical requirements for tent pads and tent platforms, the tent pads and tent platforms...
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....