Anti-Slip Protection at Every Elevator Entrance Anti-slip elevator sills protect passengers in commercial building elevators. American Safety Tread cast metal elevator sills have...
Search Results "Vertical Platform Lift"
Commonly Searched Documents
- American Safety Tread Co., Inc. Style Narrow Width Elevator Sill
-
Extended Ground or Deck Surface: ADA Standard Section 1005.3.2
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (760 mm) wide minimum...
-
11B-1005.3.2 Extended ground or deck surface
The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided and shall be 30 inches (762 mm) wide minimum...
-
§ 35.151(g) Assembly areas
(g) Assembly areas. Assembly areas subject to the proposed standards shall comply with the provisions applicable to assembly areas, including, but not limited to, sections 221 and...
-
§ 35.151(g) Assembly areas.
(g) Assembly areas. Assembly areas subject to this section shall comply with the provisions of the 2010 Standards applicable to assembly areas, including, but not limited to,...
-
242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
F242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
Accessible Means of Entry to Spas
A pool lift, a transfer wall, or a transfer system will be permitted to provide the required accessible means of entry....
-
242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with 1009.2; transfer walls complying with 1009.4; or transfer systems complying with 1009.5....
-
T402 Ramps and Bridgeplates
In the 2010 NPRM, the Board proposed to retain the existing requirement that ramps and bridgeplates longer than 30 inches (as well as lifts) be required to have design loads of 600 pounds...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
M303.3 includes technical criteria for changes in level at the entry to a wheelchair space as may occur at wheelchair weight scales with raised platforms....
-
Handrail Extensions
Other specifications regarding vertical supports may be addressed in other building codes....
-
10.3.1(13)
(13) Where it is necessary to cross tracks to reach boarding platforms, the route surface shall be level and flush with the rail top at the outer edge and between rails, except for a maximum...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
11B-242.4 Spas
Accessible means of entry shall comply with swimming pool lifts complying with Section 11B-1009.2; transfer walls complying with Section 11B-1009.4; or transfer systems complying with Section...
-
Section E: Route from Entrance
. (§ 303.4) E7 If the route to the voting area has stairs, is a platform lift or elevator provided?...
-
§ 36.403(e) Path of travel.
(e) Path of travel.
-
Sec.36.403(e) Path of travel
(e) Path of travel.
-
5.8.2.1 Height of Breast Platform at Time of Measurement
5.8.2.1 Height of Breast Platform at Time of Measurement Recommendation The Committee recommends measuring all knee and toe clearances when the top of the breast platform is set at...
-
Transfer Systems
Transfer Systems A transfer system consists of a transfer platform and a series of transfer steps that descend into the water....
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform....
-
Exception [1013.1, Exception]
When a condition for exception does not permit full compliance with a specific provision in the technical requirements for tent pads and tent platforms, the tent pads and tent platforms...
-
§ 38.93(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....