Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
Search Results "Maximum Reach Depth"
-
11B-809.10.7.5 Controls
-
Accessible Fishing Piers and Platforms
Sections 237 and 1005 of the 2010 Standards require at least twenty-five percent (25%) of railings, guards, or handrails (if provided) to be at a 34-inch maximum height (so that a person...
-
Re: Slope of R309 On-Street Parking Spaces
The more level they are, the more usable they will be, but a 2.08% maximum slope is not a requirement. Verified by Melissa Anderson at APA conference 2/2/18...
-
Selection of Playgrounds
Streeton, Cooke and Campbell (2004) summarized the advantage to the snowball sampling technique as an efficient way to locate hard-to-reach groups, especially when using a named contact...
-
M305.2.2.1 End Transfer Supports
Transfer supports shall be positioned along 13 ½ inches (345 mm) minimum of the depth of the transfer surface....
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed footrest to allow for a left or right transfer....
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
M305.2.3 Height (Section-by-Section Analysis)
In the MDE NPRM there was no specific requirement regarding the height of the transfer support, only that it be “within reach” of the patient (proposed M305.2.1)....
-
4.17.4 Toe Clearances
If the depth of the stall is greater than 60 in (1525 mm), then the toe clearance is not required....
-
4.17.4 TOE CLEARANCES
If the depth of the stall is greater than 60 in (1525 mm), then the toe clearance is not required....
-
Housekeeping
Ensure toiletry items are placed within reach limits for those with limited reach range. Towels must be within reach range -no higher than 48 inches....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
Platform Edges
Platform Edges The detectable warning must be placed at the platform edge and extend the full platform length in a 24 inch depth. This depth is an absolute dimension, not a minimum....
-
Thresholds: ADA Standard Section 608.7
Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
-
Permitted Protrusions in Wheelchair Spaces: ADA Standard Section 1002.4.4.3
Objects are permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...