Clear Deck Space Clear deck space must be provided to enable a person to get close enough to the pool lift seat to easily transfer from a wheelchair or mobility device....
Search Results "Portable Seating"
-
Clear Deck Space
-
Transfer Protocols
Two participants (P2 and P3) did not attempt to transfer higher or lower than their mobility seat for different reasons. ...
-
Transfer Protocols
This measurement was made from the ground to the top of the yellow seat cushion that is on the station (Table 2) when the participant was not seated on the station after they had returned...
-
Transfer Heights
For instance, level seat heights were 21.7± 1.2 inches and 22.1±1.4 inches for the first and second phases respectively....
-
I. BACKGROUND AND JURISDICTION
In addition, the United States alleges that accessible seating should have been provided in each specialty seating area that provides spectators with distinct services or amenities that...
- Whitehall Mfg. WH2105BAR Bariatric Toilet Siphon Jet Type Off-Floor
-
Portable tactile maps
Portable tactile maps A variety of techniques have been used to produce portable tactile maps....
-
Examples of access:
Exam table that lowers to 17-19 inches from the floor Many people find these tables easier to use. There are many ways to help people get access. See the [images]...
-
M301.4.1 Clearance in Base
[See subsections ...]
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
For example, the wheelchair footrests would be allowed to extend beyond the depth of the raised platform and over any edge protection on wheelchair weight scales used by patients seated...
- NetCentric Technologies Inc. CommonLook PDF GlobalAccess Software
- NetCentric Technologies Inc. CommonLook PDF Validator Software
- Guldmann Excellent Ramp System
-
Transfer Surface Height (M301.2.1 and M302.2.1)
For many patients who use mobility devices, independent transfer is possible only if the height of the transfer surface is at or near the seat height of their mobility device....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
Proposed § 36.406(f)(2) reiterates the longstanding requirement that wheelchair and companion seating must be integrated in the seating area, and adds a new prohibition: that the seating...
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND THE CAVALIERS OPERATING COMPANY, LLC
[See subsections ...]
-
M303.2 Wheelchair Spaces
Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment.
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...