The goal of Crytico.com is to remove the barriers that exist in the mobility industry between consumers, dealers (retailers), and manufacturers. We want to bring these interested...
Search Results "Patient Lift"
- Crytico
- Federal Elevator Systems, Inc. Showroom
-
E. Chapter 4: Boarding and Alighting
Chapter 4 in the 2016 Non-Rail Vehicle Guidelines, which sets forth the technical requirements for ramps and bridgeplates, accessible means of level boarding and alighting, lifts, and steps...
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
In addition, the Access Board has found that the profile of the base components should increase toward the rear of the clearance space where a patient’s foot and toes will be higher than...
-
4.1.6(1)(b)
installed where none existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb Ramps; 4.8, Ramps; 4.10, Elevators; or 4.11, Platform Lifts...
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
The limitation on edge protection height will reduce the possibility that the edge protection will interfere with the patient’s footrest. 5.8.1.2.2 Single Ramp Scale with Edge Protection...
-
§ 38.125(b)(6) Platform surface
The lift platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant....
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
T502.2.2 Other Vehicles
For other non-rail vehicles, the vertical clearance at doorways shall be 56 inches (1420 mm) minimum on small non-rail vehicles and 68 inches (1725 mm) on large non-rail vehicles.
-
§ 38.23(b)(6) Platform surface
(6) Platform surface. The platform surface shall be free of any protrusions over 1/4 inch high and shall be slip resistant. The platform shall have a minimum clear width of 28 1/2...
-
§ 38.83(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and...
-
§ 38.159(b)(8) Platform entrance ramp
(8) Platform entrance ramp. The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75...
-
Level boarding
If not using a lift or ramp to provide level boarding, the grantee must submit to FTA a demonstration of equivalent facilitation....
-
382.99 What agreements must carriers have with the airports they serve?
Consistent with the present rule, carriers serving U.S. airports must have agreements with the airport operators to provide, operate, and maintain lifts and ramps used to meet the boarding...
-
a. Knee and Toe Clearance
The requirements are intended to ensure that there is adequate space for a patient seated in a wheelchair to position underneath the equipment and align themselves against the breast platform...
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3.
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. A clear floor space...
-
M305.3.2 Height
The height of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve. Horizontal standing...
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum.
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the...
-
805.3 Clear Floor or Ground Space
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface. There were no public comments on this...
-
M303.3 Entry (Section-by-Section Analysis)
This is an introductory section.
-
805.3 Clear Floor or Ground Space