The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
Search Results "Patient Lift"
Commonly Searched Documents
-
M302.2.1 Adjustability (Section-by-Section Analysis)
- Horton Automatics Engineered with Purpose
- Horton Automatics Product Slideshow
- Defining and Delivering Disability-Competent Care - Building a Disability-Competent Provider Network
-
DOJ Compliance Highlights
Vans of 15 passengers or larger are required to have a lift. If you have smaller vans then you must contract with a company for use as needed....
-
Universal Design for Health Care Facilities
Universal Design for Health Care Facilities: Addressing Safety, Access to Care for a Diverse Patient Population Environment of Care® News, January 2009, Volume 12, Issue 1 Copyright...
- Implementing the Affordable Care Act (ACA): A Roadmap for People with Disabilities
-
H. Your Obligation to Provide Services and Equipment
382.39(a)] More specifically, you must provide, as needed, the following: services personnel ground wheelchairs boarding wheelchairs ramps or mechanical lifts...
-
Scoping [4.1.3(5)]
Vertical access by other means (ramp or lift) is not required to upper stories in exempt facilities....
-
§ 35.150(b)(4)(ii)
(ii) Where an existing swimming pool has at least 300 linear feet of swimming pool wall, it shall comply with the applicable requirements for swimming pools, except that it shall...
-
4.1.6(1)(f)
(f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible...
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.2.4.2 Other Equipment
Wheelchair spaces beneath diagnostic equipment other than breast platforms shall comply with M303.2.4.2.
-
F223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M305.3.2.1 Horizontal Position
The height of the top of the gripping surface on horizontal standing supports shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
The MDE NPRM proposed edge protection on the ramps leading up to the raised platform (proposed M303.3.3.4), but did not require edge protection on the raised platforms themselves....
-
223.3 Long-Term Care Facilities
In licensed long-term care facilities, at least 50 percent, but no fewer than one, of each type of resident sleeping room shall provide mobility features complying with 805.
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.