Search Results "Patient Lift"
Commonly Searched Documents
-
Level boarding
-
M303.2 Wheelchair Spaces
Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...
-
M305.3.3 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to prohibit standing supports from rotating in their fittings. There were no comments on this section and it was not addressed by the MDE Advisory Committee....
-
805.2 Turning Space
Turning space complying with 304 shall be provided within the room.
-
805.2 Turning Space
Turning space complying with 304 shall be provided within the room.
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
5.3.3 Transfer Sides Recommendations for M302
5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
805.2 Turning Space
805.2 Turning Space. Turning space complying with 304 shall be provided within the room.
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
11B-805.2.3 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
382.99 What agreements must carriers have with the airports they serve?
Consistent with the present rule, carriers serving U.S. airports must have agreements with the airport operators to provide, operate, and maintain lifts and ramps used to meet the boarding...
-
b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
In addition, the Access Board has found that the profile of the base components should increase toward the rear of the clearance space where a patient’s foot and toes will be higher than...