Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
Search Results "Door Maneuvering Clearance"
-
11B-216.4.1 Exit doors
-
408.4.3 Platform to Hoistway Clearance
The platform to hoistway clearance shall comply with 407.4.3....
-
408.4.3 Platform to Hoistway Clearance
The platform to hoistway clearance shall comply with 407.4.3....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. [2010 ADAS] Advisory 1003.3 Clearances. ...
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. [2010 ADAS] Advisory 1003.3 Clearances....
-
11B-1003.3 Clearances
Clearances at boat slips and on boarding piers at boat launch ramps shall comply with Section 11B-1003.3. Advisory 11B-1003.3 Clearances....
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
11B-404.2.7 Door and gate hardware
Exceptions: Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles...
-
4.32.3 Knee Clearances
If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see...
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall...
-
11B-404.2.7 Door and gate hardware
Existing locks shall be permitted in any location at existing glazed doors without stiles, existing overhead rolling doors or grilles, and similar existing doors or grilles that are designed...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
- BEA Inc. LZR-Microscan Swinging Door Sensor
-
Knee and Toe Space Depth
[See subsections ...]
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture. ...
- Besam SL500 A01 sliding door with outstanding performance
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
-
Clearance: ADA Standard Section 604.9.2
Section 604.9.2 covers the current ADA Standards for clearances around children's use water closets.
- Visitability
-
Clear With [sic] [§404.2.3]
Clear With [sic] [§404.2.3] The clear width is measured from the stop to the face of doors or gates open 90⁰ (or to the leading edge of sliding or folding doors....
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....