Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
306.2.3 Minimum Required Depth
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
306.2.3 Minimum Required Depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....
-
9.2.2(3)
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
Figure M6: M303.2.4 Knee and Toe Clearance
[See subsections ...]
-
Q4.) Are conditions like door closers that require force in excess of the maximum allowed by the standards considered true tolerances or are they simply non-compliance with the maintenance requirements of 35.133 or 36.211?
A4.) In our opinion, the plain language of the term “Construction and Manufacturing Tolerances” does not include adjustable conditions that can meet the detailed requirements when...
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Handrail Clearance and Cross Section [§505.5, §505.7] Surface requirements and clearances facilitate a power grip along the length of handrails....
-
Requirement 3. Usable doors.
Section 100.205(c)(2) provides that covered multifamily dwellings with a building entrance on an accessible route shall be designed in such a manner that all the doors designed to allow...
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum....
-
§ 38.25 Doors, steps and thresholds
[See subsections ...]
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on....
-
B4. Vertical Clearance
B4. Is the vertical height for the vehicle route to the loading zone, the drop off area, and the exit at least 114 inches (9 feet 6 inches) in height? [ADA Stds 4.6.5] Yes _____...
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
Knee & Toe Space [M303.2.4]
Rationale The issue of Clearance and Unobstructed Floor Space The knee and toe clearance dimensions, as well as the unobstructed floor space dimensions, dictate how close a patient...