Section 703.5 provides specifications for visual characters which address finish and contrast, case, style, character proportions and height, height, stroke thickness, and character and...
Search Results "Non-Glare Finish"
Commonly Searched Documents
-
Visual Characters
-
R210.3 Shared Use Paths
Objects shall not overhang or protrude into any portion of a shared use path at or below 2.4 m (8.0 ft) measured from the finish surface....
-
Clear Floor Space [4.16.2]
doors cannot swing into the clear floor space required at any fixture the 18 inch water closet centerline is absolute The 18 inch dimension is measured from the finished...
-
III-7.5165 Signage
. , men's and women's rooms, room numbers, exit signs) must have raised and Brailled letters; must comply with finish and contrast standards; and must be mounted at a certain height and...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
3) Signs
3) Signs ADAAG: * Signs designating permanent rooms and spaces (men's and women's rooms; room numbers; exit signs) must have raised and Brailled letters; must comply with finish and...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
An accessible route to a building entrance is impractical due to unusual characteristics of the site when: The original site characteristics result in a difference in finished grade...
-
11B-809.10.7.3 Reinforcement for grab bars
Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor....
-
11B-809.12 Electrical receptacles, controls and switches
Where there is no obstruction, 48 inches (1219 mm) maximum measured from the top of the receptacle box and 15 inches (381 mm) minimum measured from the bottom of the receptacle box to the finish...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
608.2.2 Standard Roll-In Type Shower Compartments
Note: Inside finished dimensions measured at the center points of opposing sides. Figure 608.2.2 Standard Roll-In Type Shower Compartment Size and Clearance...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Note: inside finished dimensions measured at the center points of opposing sides Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
602.2 Clear Floor Space
EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3½...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
504.4 Templates (Section-by-Section Analysis)
It is much easier to start with an accessible template as compared to adding accessibility features to otherwise finished content....
-
4.25.3 Height
Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach....
-
Signage
Directional signage must meet requirements for character proportion [4.30.2] and height [4.30.3], sign finish and contrast [4.30.5] and should include the access symbol [4.30.7]....
-
4.28.3(7)
In large rooms and spaces exceeding 100 ft (30 m) across, without obstructions 6 ft (2 m) above the finish floor, such as auditoriums, devices may be placed around the perimeter, spaced...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....