In addition, this document includes technical requirements based on children's dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
Search Results "Toilet Building"
Commonly Searched Documents
- 
    
  
  102 Dimensions for Adults and Children
  
 - 
    
  
  202.2 Additions
  
Each addition to an existing building or facility shall comply with the requirements for new construction....
 - 
    
  
  Recessed Lavatories
  
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
 - 
    
  
  202.2 Additions
  
Each addition to an existing building or facility shall comply with the requirements for new construction....
 - 
    
  
  Sec.36.603 Filing request for certification
  
Sec.36.603 Filing request for certification.
 - 
    
  
  Finish and Contrast: ADA Standard Section 703.5.1
  
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
 - 
    
  
  11B-703.5.1 Finish and contrast
  
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
 - 
    
  
  CASI California Survey Reports Acceptance Criteria - Construction and Manufacturing Tolerances AC 02-12
  
________________________________ Proposed 10-17-12 Discipline: Access Compliance References: CBSC Part 2, 11B-104; ADAS The meaning and use of regulations in the California Building...
 - ASI Global Partitions Phenolic Color-Thru
 - ASI Global Partitions Phenolic Black Core Partition
 - ASI Global Partitions Plastic Laminate Partitions
 - Scranton Eclipse Partitions
 - ASI Global Partitions Powder Coated Steel Partitions
 - Bradley 2-Stall Seat Cover/Tissue Dispenser & Napkin Disposal 5911
 - 
    
  
  4.1.6(3)(e)(ii)
  
(ii) Where it is technically infeasible to install a required standard stall (Fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e., removal of a water...
 - 
    
  
  5.3.2.3 Slope
  
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions. Exception: When the surface is not paved or is...
 - 
    
  
  § 35.151(b)(4)(iii)(B) 
  
(B) Costs that may be counted as expenditures required to provide an accessible path of travel may include:
 - 
    
  
  § 38.107(a)(4)
  
(4) Faucets and flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls shall...
 - 
    
  
  § 38.123(a)(5)
  
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches. Doorways on the side wall shall have a minimum clear...
 - 
    
  
  11B-809.10.7.5 Controls
  
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
 - 
    
  
  General Preamble
  
usually public in nature, which provide informational or transactional capabilities, including, but not limited to fare machines, vending machines, automated teller machines, electronic building...
 - 
    
  
  11B-805 Medical care and long-term care facilities
  
Toilet rooms that are accessed from an examination, diagnostic or treatment room shall also be accessible....
 - 
    
  
  III-7.5165 Signage
  
must comply with finish and contrast standards; and must be mounted at a certain height and location. 2) Signs that provide direction to or information about functional spaces of a building...
 - 
    
  
  11B-202.2 Additions
  
Each addition to an existing building or facility shall comply with the requirements for new construction and shall comply with 11B-202.4 _|Alterations; Path of Travel Requirements|_....