606.4 Faucets and Water Spray Units The final rule revises this section to require a water spray unit to be provided at the kitchen sink in emergency transportable housing units required...
Search Results "Covered Dwelling Unit (CBC 11A)"
-
606.4 Faucets and Water Spray Units
-
11B-233.3.1.2.6 Public housing facility site impracticality
The requirements in this section were previously found in Chapter 11A. Please see section 1150A.1 for the 2019 Chapter 11A language....
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
- Bobrick B-30929 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- Bobrick B-30919 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
804.3 Kitchen Work Surface (Exception)
804.3 Kitchen Work Surface (Exception) This section requires at least one work surface to be provided at kitchen counters in residential dwelling units required to provide mobility features...
-
23.1 Q. What type of reinforcement should be used to reinforce bathroom walls for the later installation of grab bars?
A. The Guidelines do not prescribe the type of material to use or method of providing reinforcement for bathroom walls. The Guidelines recognize that grab bar reinforcing may be...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
7(2)(a)(ii)
(ii) Clear floor space is provided at fixtures as shown in Fig. 7 (a), (b), (c) and (d). Clear floor space at fixtures may overlap. Fig. 7 Clear Floor Space for...
-
§100.205(a)
(a) Covered multifamily dwellings for first occupancy after March 13, 1991 shall be designed and constructed to have at least one building entrance on an accessible route unless it is impractical...
-
F202.3 Alterations
Residential dwelling units not required to be accessible in compliance with a standard issued pursuant to the Architectural Barriers Act or Section 504 of the Rehabilitation Act of 1973,...