Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
Search Results "Exit Ramp"
-
Character Proportions: ADA Standard Section 703.5.4
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
12 [§ 4.7.9]
12 [§ 4.7.9] When a curb ramp is located at a marked crossing, the area where the ramp run ends must be contained within the marked crossing....
-
Sidewalks and Walkways
Some sidewalks do not include curb ramps or, if they do, the ramped section is too narrow or steep....
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with this section and Section 11B-809.8....
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
1015.3 Height
On ramps and ramped aisles, from the ramp surface at the guard....
-
203 General Exceptions
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
-
R207.1 General
A curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with R304 shall connect the pedestrian access routes at each pedestrian street crossing....
-
Problem Two (Accessible Route)
Problem Two: The accessible route crosses a curb and no curb ramp is provided. Solution: Install a portable ramp....
-
3. Exception to Ramp Running Slope
A ramp in the built environment to which this exception applies may use a 1:2 grade slope on a short rise ramp....
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
1007.6.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
1003.2.13.5.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
§ 38.125(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Governmental Units Affected (R208 Detectable Warning Surfaces) (Section-by-Section Analysis)
The Access Board seeks information on whether any state and local transportation departments currently use UFAS for curb ramps in the public right-of-way....
-
§ 38.159(c)(1) Design load
Ramps 30 inches (760 mm) or longer shall support a load of 600 pounds (2665 N), placed at the centroid of the ramp distributed over an area of 26 inches by 26 inches (660 mm by 660 mm),...