Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp and shall comply with 4.8....
Search Results "Exit Ramp"
-
4.8.1* General
-
4.8.1* GENERAL
Any part of an accessible route with a slope greater than 1:20 shall be considered a ramp and shall comply with 4.8....
-
Slope [§405.2] and Cross Slope [§405.3]
Specifying a running slope of 7.5% maximum and a cross slope of 1.5% maximum for exterior ramps will accommodate most irregularities or variances due to construction methods or materials...
-
f-vi
Is there a level landing, at least 60 inches x 60 inches, when a ramp changes direction? [ADA Standards § 4.8.4] Yes No...
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides....
-
Signage Requirements in the 2010 Standards for Accessible Design
The purpose of the SEGD 2012 ADA White Paper Update is to help the EGD community meet the spirit and intent of the new SAD accessible guidelines.
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
Circular Cross Section: ADA Standard Section 505.7.1
Section 505.7.1 covers the current ADA Standards for the circular cross section of handrail gripping surfaces.
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be...
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be...
- citEcar ADA Electric Shuttle 11P 1WC