Advisory 11B-405.7.5 Doors at ramp landings....
Search Results "Elevator Car Door"
Commonly Searched Documents
-
11B-405.7.5 Doorways
-
Door stop
[See subsections ...]
-
11B-404 DOORS, DOORWAYS, AND GATES
[See subsections ...]
-
Common Questions (Entrances, Doors, and Gates)
Common Questions
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
Keypads: ADA Standard Section 407.2.1.6
Section 407.2.1.6 covers the current ADA Standards for elevator keypads.
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4. [2010 ADA Standards] 407.2.1 Call Controls....
-
Accessible entrances that have turnstiles must provide an accessible gate or door.
• Accessible entrances that have turnstiles must provide an accessible gate or door....
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....
-
Can doors swing into turning space?
Yes, doors can swing into turning space....
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf....
-
§ 38.125(b)(2)(i) Requirements
The controls shall be interlocked with the car brakes, propulsion system, or door, or shall provide other appropriate mechanisms or systems, to ensure that the car cannot be moved when the...
-
Alterations to elevators. (Section-by-Section Analysis)
Alterations to elevators....
-
3. Measuring Door Openings
Measuring Door Openings Special care is needed when measuring the clear opening of a doorway. To measure the clear opening of a standard hinged door, open the door to 90 degrees....
-
409 Private Residence Elevators
409 Private Residence Elevators...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
III-7.5115 Elevators and platform lifts
III−7.5115 Elevators and platform lifts (ADAAG §4.1.3(5))....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...