Doors with 32 inches of clear opening width (when a sliding door is fully opened or a hinged door is open 90 degrees). Clear floor space is required in front of the door....
Search Results "Elevator Car Door"
Commonly Searched Documents
-
3. Doors
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and 0-16...
-
4.13.11(2)(c)
(c) sliding or folding doors: 5 lbf (22.2N) These forces do not apply to the force required to retract latch bolts or disengage other devices that may hold the door in a closed position...
-
Low Energy Doors and Gates [§404.3]
Low Energy Doors and Gates [§404.3] Low energy doors and gates usually require activation by the user through a push plate or control and are often used in moderate traffic locations...
-
SECTION 1132A DOORS
SECTION 1132A DOORS...
-
12162(a)(1) One car per train rule
(1) One car per train rule It shall be considered discrimination for purposes of section 12132 of this title and section 794 of title 29 for a person who provides intercity rail transportation...
-
A. Slope at Door
If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons who use wheelchairs...
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
407.2 Elevator Landing Requirements
407.2 Elevator Landing Requirements. Elevator landings shall comply with 407.2....
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2....
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
407.4.6.4.2 Location
407.4.6.4.2 Location. Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
4.10.12(3)
(3) Height. All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach. Emergency controls, including...
-
4.10.12(3)
(3) Height. All floor buttons shall be no higher than 48 in (1220 mm), unless there is a substantial increase in cost, in which case the maximum mounting height may be increased to...
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel.
-
11B-603.2.3 Door swing
[2010 ADA Standards] 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.2.1 Revolving doors, gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....