407.4.7.2 Keypads. Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single...
Search Results "Visible Signal (Elevator Landing)"
Commonly Searched Documents
-
407.4.7.2 Keypads
-
407.2.1.1 Height
407.2.1.1 Height. Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part. EXCEPTION:...
-
407.4.8.1.2 Location
407.4.8.1.2 Location. Indicators shall be located above the car control panel or above the door.
-
409.2 Call Buttons
409.2 Call Buttons. Call buttons shall be ¾ inch (19 mm) minimum in the smallest dimension and shall comply with 309.
-
11B-407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door.
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309 _|Operable Parts|_.
-
11B-409.2 Call buttons
Call buttons shall be ¾ inch (19.1 mm) minimum in the smallest dimension and shall comply with Section 11B-309.
-
11B-407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door.
-
407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of 1/2 inch (13 mm) under rated loading to...
-
1008.3 Transfer Systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems....
-
1008.3 Transfer Systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems....
-
1008.3 Transfer Systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with 1008.3. Advisory 1008.3 Transfer Systems....
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. [2010 ADAS] Advisory 1008.3 Transfer Systems. ...
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. [2010 ADAS] Advisory 1008.3 Transfer Systems....
-
11B-1008.3 Transfer systems
Where transfer systems are provided to connect to elevated play components, transfer systems shall comply with Section 11B-1008.3. Advisory 11B-1008.3 Transfer systems....
-
11B-407.2.1.2 Size and shape
[2010 ADAS] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
11B-407.2.1.2 Size and shape
[2010 ADAS] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
11B-407.2.1.2 Size and shape
[2010 ADA Standards] EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
- Step Hear CH-100 Call Unit Service Button
-
3b.
Is an elevator provided or lift provided? Yes _____ No _____ If an elevator is provided, go to question E1-5. If a lift is provided, go to question E1-6....
-
407.1 General
Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger elevators as classified by ASME A17.1....
-
407.1 General
Elevators shall comply with 407 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1). They shall be passenger elevators as classified by ASME A17.1....
-
9.a [§ 4.7.5]
9.a [§ 4.7.5] If the sidewalk at the top of the ramp (“x” in the illustration) is 48 inches wide or more, answer this question. If “x” is less than 48 inches, skip this question...
-
9.b [§ 4.7.5]
9.b [§ 4.7.5] If the sidewalk at the top of the ramp (“x”) is less than 48 inches wide and the curb ramp you are surveying has flared sides, answer this question. Otherwise, skip...