section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear floor space of 48 inches by 30 inches, which do not unduly restrict...
Search Results "Restricted Entrance"
-
§ 38.83(a)(1) General
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5)....
-
11B-502.3 Access aisle
Accessible routes must connect parking spaces to accessible entrances....
-
11B-502.3 Access aisle
Accessible routes must connect parking spaces to accessible entrances....
-
3.2 Why Is a Reasonable Accommodation Necessary?
For this reason, the ADA requires reasonable accommodation as a means of overcoming unnecessary barriers that prevent or restrict employment opportunities for otherwise qualified individuals...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
§ 35.151(b)(4)(iii)(B)(1)
(1) Costs associated with providing an accessible entrance and an accessible route to the altered area, e.g., the cost of widening doorways or installing ramps;...
-
A8. Accessible Route
Are the accessible parking spaces serving the voting area on the shortest accessible route to the accessible entrance? [ADA Stds 4.6.2] Yes _____ No _____...
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space....
-
Restaurants and Cafeterias: ADA Standard Section 206.2.5
Section 206.2.5 covers scoping requirements in the most current ADA Standards for accessible routes in restaurants and cafeterias
-
11B-232.1 General
Buildings, facilities, or portions thereof, in which people are detained for penal or correction purposes, or in which the liberty of the inmates is restricted for security reasons shall...
-
11B-232.1 General
Buildings, facilities, or portions thereof, in which people are detained for penal or correction purposes, or in which the liberty of the inmates is restricted for security reasons shall...
-
F. Check-In Areas
Check-In Areas A shelter usually has one or more check-in areas located near the entrance to the shelter....
-
10.3.1(1)
The circulation path, including an accessible entrance and an accessible route, for persons with disabilities shall, to the maximum extent practicable, coincide with the circulation path...
-
F1
Is there an accessible route that connects the accessible entrance to areas that are likely to be used to register people as they arrive at the shelter?...
-
§100.201 Ground floor
Ground floor means a floor of a building with a building entrance on an accessible route. A building may have more than one ground floor....
-
Feature 4 - Routes to the Meeting Space
Feature 4 - Routes to the Meeting Space Accessible interior routes to the meeting space The interior accessible route connects the accessible entrance with the meeting space....
-
Section B: Passenger Drop-Off Area
(§503.4) B3 Is there vertical clearance of at least 114" (9 feet 6 inches) from the site entrance to the vehicle pull-up area, in the access aisle...
-
B9
Does each access aisle connect to an accessible route from the parking area to the shelter's accessible entrance? [ADA Standards § 4.6.2] Yes No...
-
A9. Accessible Route
Does each access aisle connect to an accessible route from the parking area to the accessible building entrance? [ADA Stds 4.6.2] Yes _____ No _____...
-
12101(a)(8)
122 Stat. 3553, provided that: (8) Congress finds that the current Equal Employment Opportunity Commission ADA regulations defining the term "substantially limits" as "significantly restricted...
-
A4.2.1(1) Space Requirements for Wheelchairs
However, when an opening or a restriction in a passageway is more than 24 in (610 mm) long, it is essentially a passageway and must be at least 36 in (915 mm) wide....
-
A4.2.1(1) Space Requirements for Wheelchairs
However, when an opening or a restriction in a passageway is more than 24 in (610 mm) long, it is essentially a passageway and must be at least 36 in (915 mm) wide....
-
Angled Van Spaces
Recommendation: Where standard (non-van) accessible spaces are angled or otherwise restrict entry to one direction only, providing one access aisle for each accessible space (or on both...