* The minimal signal to noise ratio at the receiver's output should not be less than 35 dB. Harmonic distortion shall not be more than 10%....
Search Results "Door Signal Device"
Commonly Searched Documents
-
2.2.2.2 New York State Standards
-
2.4.1. Replacement Costs
The Final RA estimates the costs to replace captioning and audio description hardware and devices over the time frame of the analysis. ...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
3.0 Comparison of Research Methodologies
size, reaching, maneuvering, door use Seeger, Costi and Hartridge, 1994, AUS 240, all devices. 75% from institutions 2-D, manual measurements...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
3.3.3 Clear Floor Width
Neither the DfT or DETR studies collected data on occupied width but did measure the unoccupied device width....
-
Is latch-side maneuvering clearance as specified in the Standards applicable to doors with panic bars?
When latch-side clearance is required as part of the maneuvering clearances specified for a door, including on the push side of doors with a forward approach that have both a closer and...
-
H24
Unless the wide stall is located at the end of a row of toilet stalls, does the door to this wider stall open out? [ADA Standards § 4.17.3] Yes No...
-
§ 36.311(a) Use of wheelchairs and manually powered mobility aids
A public accommodation shall permit individuals with mobility impairments to use wheelchairs, scooters, walkers, crutches, canes, braces, or similar devices in any areas open to pedestrian...
-
21. BRAND STANDARDS, QUALITY ASSURANCE INSPECTIONS
(vi) The required number of permanent or portable visual alarms and notification devices for incoming telephone calls and door knock or bell to ensure that the hotel can fully equip the...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
§ 38.159(a)(2) Exception
provided at stations or other stops required to be accessible under regulations issued by the Department of Transportation, the bus is not required to be equipped with a vehicle-borne device...
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Door Arm Pivot Variations Video
- ADAEZ Pro Plus Automatic Door Opener Quick Tip Adjusting Spring Door Tension Video
-
2.1.4. Venue Type
The number of hardware units and individual devices required by the rulemaking are the building blocks of the cost estimation for the average movie theater of each venue type. ...
- Access Board: Automatic Door Controls
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
3.3. Scoping Requirements
This section outlines the estimated number of hardware units and individual devices required for each venue type. ...
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
-
1132A.5 Maneuvering clearances at doors
[See subsections ...]
- Boost Your Business - Chapter 6 - Doors