The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
Search Results "Door Signal Device"
Commonly Searched Documents
-
Disinformation Corridor Exhibit
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Architect
The 4040XP provides adjustments for Position 1-6, has a range of interior and exterior door sizes it can work on....
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
D4. Door Clearance
On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?...
-
Automatic and Power-Assisted Doors and Gates [§404.3]
Automatic and Power-Assisted Doors and Gates [§404.3] Doors are not required to be automated, but must comply when provided....
-
3.3.6 Knee Clearance Height, minimum
3.3.6 Knee Clearance Height, minimum Knee clearance heights for the four sets of standards range from 650 mm (25.6 in.) (Australia) to 700 mm (27.6 in.) (U.K.) (Figure 3‒6). The...
-
3.3.5 Seat Height
3.3.5 Seat Height Height dimension standards for seats prescribed in the Australian, Canadian and U.S. standards were very similar (480 mm or 18.9 in., 480 mm or 18.9 in. and 485...
-
3.3.8 Knee Clearance Depth, minimum
3.3.8 Knee Clearance Depth, minimum Knee clearance depths for the four sets of standards range from 200 mm (8 in.) in Canada to 280 mm (11 in.) in the U.S. (Figure 3‒8). None of...
-
3.3.7 Toe Clearance Height, minimum
3.3.7 Toe Clearance Height, minimum There is relatively large disparity between the standards for toe clearance height, with the U.S. having the lowest (230 mm or 9 in.),...
-
3.3.9 Toe Clearance Depth, minimum
3.3.9 Toe Clearance Depth, minimum Toe clearance depths for the standards range from 150 mm (6 in.) in the U.S. to 230 mm (9 in.) in Canada (Figure 3‒9). None of the comparison...
-
§ 38.23 Mobility aid accessibility
[See subsections ...]
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
Guest Rooms
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
2.4.1. Replacement Costs
The Final RA estimates the costs to replace captioning and audio description hardware and devices over the time frame of the analysis. ...