Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
Search Results "Tape Measure"
Commonly Searched Documents
-
604.9.6 Dispensers
-
404.2.4.3 Recessed Doors and Gates
clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured...
-
§ 36.303(c)(1)(ii)
should consult with individuals with disabilities whenever possible to determine what type of auxiliary aid is needed to ensure effective communication, but the ultimate decision as to what measures...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm)....
-
4.13.5 Clear Width
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the opposite stop (see Fig. 24(a), (b), (c), and (d...
-
E102.8 Telecommunications Industry Association (TIA)
TIA 1083 defines measurement procedures and performance requirements for the handset generated audio band magnetic noise of wire line telephones, including digital cordless telephones....
-
III-9.8000 Certification and barrier removal in existing facilities
The Department will measure equivalency against subpart D of the title III rule, New Construction and Alterations....
-
Can handrails or other elements overlap door maneuvering clearances?
The door maneuvering clearance must be measured from the leading edge of such elements so that the full clearance is free of any obstruction....
-
4 - Best practices for construction observation
Even though the final responsibility rests with the contractor, the architect, or other design professional should be observing construction and requiring the contractor to use the measurement...
-
Can handrails overlap door maneuvering clearances?
The door maneuvering clearance must be measured from the leading edge of such elements so that the full clearance is free of any obstruction....
-
11B-603.6 Guest room toilet and bathing rooms
that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring...
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
11B-804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware. ◼...
-
ASTM: ADA Standard Section 105.2.3
Section 105.2.3 of the ADA Standards cover references to the American Society for Testing and Materials (ASTM) standards.
-
Updates and Other Pocket Guides
For ADA survey and compliance tools that will simplify your field measurement process and plan reviews, the Corada Shop has a growing collection of templates and tools that you can download...
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
11B-707.4 Privacy
., a covered entity does not have to take measures that would result in a fundamental alteration of its program or would cause undue burdens, provide adequate protection to operators of...
-
Auxiliary Aids and Services for Students with Disabilities
assistive listening systems accessible electronic and information technology open and closed captioning a portable device that writes and/or produces speech taped...
-
B. EFFECTIVE COMMUNICATION
., Braille, large print, cassette tapes)....
- Sloan Optima® Sensor-Activated Soap Dispenser ESD-200, 250
- Bobrick Toilet Tissue Dispenser with Stainless Steel Hood B-699
- Whitehall Mfg. 4122ADA Two-Station Compact Scrub Sink