Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
Search Results "Perpendicular Transfer"
Commonly Searched Documents
-
11B-810.2.2 Dimensions
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured perpendicular...
-
Addendum A: List of Terms
Independent Transfer: a transfer that can be completed without the assistance or intervention Level Transfer- A transfer where the transfer surface is at the same height as the wheelchair...
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel....
-
405.3 Cross Slope
Cross slope is the slope of the surface perpendicular to the direction of travel. Cross slope is measured the same way as slope is measured (i.e., the rise over the run)....
-
Back Support: ADA Standard Section 903.4
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS MINIMUM MANEUVERING CLEARANCE Approach direction Perpendicular...
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
4.5.4 Gratings
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
4.5.4 GRATINGS
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces...
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces ...
-
§ 38.101(b)
lighted station platforms shall have outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform surface for a distance of 3 feet perpendicular...
-
11B-404.2.4.3 Recessed doors and gates
the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior doorway, projects more than 8 inches (203 mm) beyond the face of the door, measured perpendicular...
-
11B-404.2.4.3 Recessed doors and gates
the latch side at an interior doorway, or within 24 inches (610 mm) of the latch side of an exterior doorway, projects more than 8 inches (203 mm) beyond the face of the door, measured perpendicular...
-
Armrests M302.3.2
If provided armrests cannot interfere with transfer supports during the transfer....
-
Medical Diagnostic Equipment: ADA Standard Section 5.
Review the updated information on the revisions to the ADA Standards regarding medical diagnostic equipment.
-
1009.7.2 Separation
wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction is permitted to extend out perpendicular...
-
4 [§ 4.7.2]
The gutter slope is parallel to the ramp and perpendicular to the curb. The gutter may slope up to 5 percent towards the curb ramp, but not more....