42" (1065mm) long, 1-1/4" (32mm) dia. tubing. Constructed of 18-gauge (1.2mm), type 304 satin-finish stainless steel tubing. Concealed mounting flange 1/8" (3mm) thick, type 304...
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
- Bobrick 42" Straight Grab Bar B-5806 x 42
- Moen Home Care Peened 42" Grab Bar
-
A4.27.3 Height
Fig. A8 further illustrates mandatory and advisory control mounting height provisions for typical equipment. Electrical receptacles installed to serve individual...
-
3.5.3 Signs in General
If materials need to be obtained from or manipulated on a sign or kiosk, the sign or kiosk shall be designed to meet the reach ranges in section 308 of the ABAAS.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply...
-
5.8.1.2.1 Ramped Entry Slope Recommendations
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
Emergency Health Information
By June Isaacson Kailes, Disability Policy Consultant Harris Family CDHP logo [sic] IEHP Logo [sic] This publication made possible through funding by Inland Empire Health...
-
Care Management/Care Coordination
# Care Management / Care Coordination (Adapted and excerpted from Disability-Competent Care Self-Assessment Tool***) Yes No Unsure Comments...
-
Care Management/Care Coordination
Disability-Competent Care Self-Assessment Tool From CMS Medicaid-Medicare Coordination Office Resources for Integrated Care Webpage...
-
2. IMPROVING PHYSICAL ACCESS
People with disabilities should be able to travel to a health care site, approach and enter and move around the building as conveniently as everyone else. Access issues that should...
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
C. Chapter 3: Technical Requirements (Section-by-Section Analysis)
In the final rule, Chapter 3 establishes the technical requirements for accessible medical diagnostic equipment based on how the diagnostic equipment is used by the patients, including:...
- Defining and Delivering Disability-Competent Care - The Care Coordination Relationship
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Imaging Equipment
Especially, Section M301, Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position....
- The Impact of the Affordable Care Act on People with Disabilities: A 2015 Status Report