The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
Search Results "Intensive Care Patient Room"
Commonly Searched Documents
-
M301.2.1 Adjustability (Section-by-Section Analysis)
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
Turning Space: ADA Standard Section 806.2.6
Turning space complying with 304 shall be provided within the guest room....
-
Invisible Wounds: Emerging Promising Practices for Meeting Planners
In a concert or large presentation hall, hold seats along the sides of the room close to exits for individuals who may experience challenges with crowds....
-
224 Transient Lodging Facilities and Guest Rooms
[See subsections ...]
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: Â General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....
-
Single-User Toilet Rooms: Side Transfer Space
Single-User Toilet Rooms: Side Transfer Space These drawings illustrate the space requirements for a single-user toilet room with a single plumbing wall....
-
F240.1 General
Play areas located in family child care facilities where the proprietor actually resides shall not be required to comply with F240. 2....
-
240.1 General
Play areas located in family child care facilities where the proprietor actually resides shall not be required to comply with 240. 2....
-
240.1 General
Play areas located in family child care facilities where the proprietor actually resides shall not be required to comply with 240. 2....
-
Multi-Story Buildings and Facilities: ADA Standard Section 206.2.3
Section 206.2.3 covers the scoping requirements in the most current ADA Standards for accessible routes within multi-story buildings and facilities
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment. An overhead lift may be used as an alternative option in lieu of the provisions for clearances in and around the...
-
B. Clear Width
Do bathroom doors in all guestrooms allow 32" clear passage width so persons who use wheelchairs, crutches, and other mobility aids can visit or stay in other rooms and use the bathroom?...
- Seton California Code ADA Women Rest Room Sign - Black 84943