If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
Search Results "Intensive Care Patient Room"
-
806.2.4.1 Vanity Counter Top Space
-
L. Accessible Guest Rooms
Accessible Guest Rooms (1) Defendants will have 12 designated accessible rooms/ suites that comply with the 2010 Standards dispersed among the various classes of accommodations as follows...
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
4.35.5 Mirror
Where mirrors are provided in dressing rooms of the same use, then in an accessible dressing room, a full-length mirror, measuring at least 18 in wide by 54 in high (460 mm by 1370 mm),...
-
11B-224.1.1 Alterations
Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
-
11B-224.1.1 Alterations
Where guest rooms are altered or added, the requirements of Section 11B-224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum...
-
Figure M2: M301.4 Lift Compatibility
(at Diagnostic Equipment for Use by a Patient in a Supine, Prone, or Side-Lying Position)...
-
Toilet Facilities and Bathing Facilities: ADA Standard Section 213
Section 213 covers scoping requirements in the current ADA Standards for toilet facilities and bathing facilities.
-
11B-213 Toilet facilities and bathing facilities
[See subsections ...]
-
11B-213 Toilet facilities and bathing facilities
[See subsections ...]
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
that medical diagnostic equipment, including but not limited to, examination tables, examination chairs, weight scales, mammography equipment, and other imaging equipment used by health care...
-
Toilet Rooms-Banquet Area
Toilet Rooms-Banquet Area: s....
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment. The transfer or positioning support should be oriented horizontally on imaging equipment with transfer...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces. Transfer supports for imaging equipment should be 28 inches minimum in length and...
-
9.2 Requirements for Accessible Units, Sleeping Rooms and Suites
[See subsections ...]
-
Protruding Objects
Protruding Objects: Some people who are blind or have low vision use canes to detect objects along a route. One element of a barrier-free meeting space for participants who are...
-
E. Smoking Rooms
E. Are smoking and non-smoking accessible guestrooms provided based upon the ratio of smoking and non-smoking guestrooms in the facility so persons with disabilities have the same...
-
4.3.5 HEAD ROOM
Accessible routes shall comply with 4.4.2.
-
Head Room [4.4.2]
Circulation paths must provide at least 80 inches of vertical clearance. Otherwise, fixed barriers detectable by canes must define areas with less clearance. Gates, rails, curbs, and...
-
Head Room [4.3.5]
The 80 inch minimum vertical clearance applies not only to accessible routes but to all circulation routes (see 4.4.2). Eighty-inch doors, including those equipped with closers, are...
-
4.3.5 Head Room
Accessible routes shall comply with 4.4.2.
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
Obstructions shall not be vertically less than 1 inch nor be horizontally more than 3 inches from the edge of the patient support surface to provide unobstructed access to the transfer surface...