Obstructions shall not be vertically less than 1 inch nor be horizontally more than 3 inches from the edge of the patient support surface to provide unobstructed access to the transfer surface...
Search Results "Intensive Care Patient Room"
Commonly Searched Documents
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
-
Guarantees of reservations for accessible guest rooms. (Section-by-Section Analysis)
Guarantees of reservations for accessible guest rooms....
- Seton Women's Rest Room ADA Braille Sign with ISA 44985
- Seton Unisex Rest Room ADA Braille Sign with ISA 44982
- Seton Men's Rest Room ADA Braille Sign with ISA 44988
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
Turning Space: ADA Standard Section 612.3
Section 612.3 covers the current ADA Standards for turning space within saunas and steam rooms.
-
11B-603.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position for Imaging Equipment. The transfer or positioning support should be oriented horizontally on imaging equipment with transfer...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces. Transfer supports for imaging equipment should be 28 inches minimum in length and...
-
Features of Accessible Exam Tables
Exam surface lowers to 17” to 19” above the floor 4. 36” wide minimum accessible route 5.Exam surface may articulate to provide support during patient transfers and positioning...
-
Accessible Theater Style
Aisle chairs can be removed in rows dispersed throughout the room to allow seating choices for people who use mobility devices or service animals....
-
11B-612.3 Turning space
A turning space complying with Section 11B-304 shall be provided within saunas and steam rooms....
-
4.1.6(1)(g)
(g) Mechanical rooms and other spaces which normally are not frequented by the public or employees of the building or facility or which by nature of their use are not required by the Architectural...
-
2. b. WIDE AND EASY TO OPEN EXTERIOR AND INTERIOR DOORS
[See subsections ...]
-
2. a. iii. Clear (Path-of-Travel) Floor Space
Access also includes how people will move into and around lobby and office reception areas, and determine the unobstructed floor or ground space to accommodate a wheelchair user....
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the...
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...