TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS MINIMUM DIMENSIONS Door Location Door clear width Inside car, side to side...
Search Results "Flared Side"
-
11B-407.4.1 Car dimensions
-
11B-805 Medical care and long-term care facilities
A 36-inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
B. Door Maneuvering Clearance
Is there adequate room for a person who uses a wheelchair to approach the restroom door from the pull side and pull it open without it hitting the wheelchair - this requires at least 18"...
-
4.17.5* Doors
If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in (1065 mm) (Fig. 30...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular to Doorway Parallel to Doorway (beyond stop/latch side...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Minimum Maneuvering Clearance Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
MINIMUM MANEUVERING CLEARANCE Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings shall extend the full width of the turning space at the demarcation between the street and the sidewalk less 2 inches (sic) (51 mm) maximum on each side....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings shall extend the full width of the turning space at the demarcation between the street and the sidewalk less 2 inches (sic) (51 mm) maximum on each side....
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
1010.1.6 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
-
1010.1.6 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
- Robert Judd, CASp, ICC, RAS
-
M1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door and centered 60 inches above the floor?...
-
1015.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
F221.2.3.1 Horizontal Dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory F221.2.3.1 Horizontal Dispersion....
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
O. Accessible Portable Toilets
For the entrance to an accessible portable toilet to be usable, there must either be no step or a ramp must be installed that extends extends from the hinge side of the door to at least...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...