by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
Search Results "Flared Side"
Commonly Searched Documents
-
11B-1009.5.2 Transfer space
-
Transfer Platforms
ground level. 11 inches (280 mm) to 18 inches (455 mm) height of top surface Minimum 24 inches (610 mm) wide Minimum 14 inches (355 mm) deep Unobstructed side...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
-
Standard Stall
Stalls should be located and configured to allow forward or latch-side approaches which provide easier wheelchair access than hinge-side approaches....
-
1133B.2.4.2
Regardless of the occupant load, there shall be a floor or landing on each side of a door. 1133B.2.4.2 Maneuvering clearances at doors. ...
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
- American Standard Madera 1.28 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Side View
- American Standard Madera 1.6 gpf ADA EverClean Toilet with Exposed Manual Flush Valve System Side View
-
Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ELKAY Filtered EZH2O® Bottle Filling Station with Integral Soft Sides® Fountain LZWS-EDFP217K Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
R406 Reach Ranges (Section-by-Section Analysis)
R406 Reach Ranges (Section-by-Section Analysis) Forward and side reach ranges must be between 380 millimeters (1.25 feet) and 1220 millimeters (4 feet) above the finish surface....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
Clear Ground Space [1011.2]
Fire rings, grills, fireplaces, and woodstoves 48 by 48 inches on all usable sides of a fire ring, grill, fireplace, and woodstove....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm)...
-
Mounting Location and Height [4.30.6]
Mounting Location and Height [4.30.6] Placement of tactile signs aside doors (latch-side) provides safety since locating signs on doors that swing out is hazardous....
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...