Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
Search Results "Flared Side"
Commonly Searched Documents
-
M304.2.2 Standing Supports
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR....
-
407.12.1 Vertical Reference Plane (Section-by-Section Analysis)
407.12.1 Vertical Reference Plane (Section-by-Section Analysis) This section proposes that the positioning of operable parts for side reaches and forward reaches be determined with respect...
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-608.2.2.1 Clearance
[2010 ADAS] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
4. Comparison of Proposed Technical Provisions Applicable to Shared Use Paths and AASHTO Guide
., manholes) and bicycle-compatible drainage grates should be flush with the surface of the pavement on all sides. . . ....
-
Station Names: ADA Standard Section 810.6.3
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
MINIMUM MANEUVERING CLEARANCE Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 11B-221.2.3.1 Horizontal dispersion....
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2)....
-
Door Maneuvering Clearance
At doors that provide a latch side approach, the minimum depth of this clearance is increased where a closer is provided because additional space is needed to counteract the force of closers...