Exception: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would...
Search Results "Existing Theaters"
-
11B-608.7 Thresholds
-
12182(b)(2)(A)(iv)
(iv) a failure to remove architectural barriers, and communication barriers that are structural in nature, in existing facilities, and transportation barriers in existing vehicles and rail...
-
302.4 Without Hearing (Section-by-Section Analysis)
This provision would clarify the requirements in existing 508 Standards §1194.31(c) and existing 255 Guidelines §1193.41(d) by specifying that provision of a mode of operation without hearing...
-
R202.1 General
Alterations and elements added to existing facilities shall comply with R202....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
5. Alternatives
Discounted at 7 Percent [$ millions] Cost category Primary analysis 2-year compliance date 6-month compliance date NPRM scoping requirement Analog theaters...
-
5.1 Public Notification of Availability
Recorded telephone information from movie houses and theaters should include a comment that ALS are available for people with hearing loss....
-
11B-404.2.10 Door and gate surfaces
Existing doors and gates without smooth surfaces within 10 inches (255 mm) of the finish floor or ground shall not be required to provide smooth surfaces complying with 404.2.10 provided...
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
11B-404.2.10 Door and gate surfaces
Existing doors and gates without smooth surfaces within 10 inches (255 mm) of the finish floor or ground shall not be required to provide smooth surfaces complying with 404.2.10 provided...
-
Restaurants and Cafeterias: ADA Standard Section 206.2.5
Section 206.2.5 covers scoping requirements in the most current ADA Standards for accessible routes in restaurants and cafeterias
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
- Elkay Filtered EZH2O® Bottle Filling Station Retro Fit Kit LMABFWS-RF
- Allied Industries International, Inc. Eco-Grip® Slip Resistant Safety Flooring
-
COMMENTS
The ADA was not intended to change existing landlord/tenant responsibilities as set forth in the lease....
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
407.1 General (Section-by-Section Analysis)
This section is consistent with requirements in existing 508 Standards §§ 1194.21 and 1194.25, along with § 1193.41(f) of the existing 255 Guidelines....
-
302.6 Without Speech (Section-by-Section Analysis)
302.6 Without Speech (Section-by-Section Analysis) This proposed section would clarify the requirements in existing 508 Standards §1194.31(e) and existing 255 Guidelines §1193.41(h) by...
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of...
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
Saunas and steam rooms. (Section-by-Section Analysis)
The Department considered these comments and has decided to eliminate the exemption for existing saunas and steam rooms that seat only two people....
-
Q8: Curb Ramp Replaced as Part of a Resurfacing Alteration and Adjacent Sidewalk
Q8: If an existing curb ramp is replaced as part of a resurfacing alteration, is there an obligation to address existing obstacles on the adjacent sidewalk at the same time? A8: No....