(4) Gripping surfaces shall be continuous.
Search Results "Bus Ramp"
Commonly Searched Documents
-
4.8.5(4)
-
R304.5.5 Clear Space
R304.5.5 Clear Space. Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street...
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
1.1.1
For example, the 1:12 slope stated in ADAAG and ADA/ABAAG is a maximum slope for ramps, not a design requirement....
-
4.7.2 SLOPE
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
DSA Drawing 11B-406-5C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
4.7.2 Slope
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11....
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Play Components: ADA Standard Section 1008.4
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
5.8.1.2.1 Ramped Entry Slope Recommendations
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the slope...
-
11B-1008.4 Play components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with Section 11B-1008.4....
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
§ 38.95(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates stowed in the passenger...
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
M303.3.3 Ramped (Section-by-Section Analysis)
The commenter, a medical association, concurred with the requirement for handrails on diagnostic equipment with ramps over six inches in height....
-
505.1 General
Handrails provided along walking surfaces complying with 403, required at ramps complying with 405, and required at stairs complying with 504 shall comply with 505....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....