Provision of accessible boarding and alighting shall be made through one or more of the following methods: ramps or bridgeplates complying with T402, lifts complying with T403, or a means...
Search Results "Bus Ramp"
-
T202.1 General
-
T205.1 General
Non-rail vehicles shall provide illumination complying with T503 at ramps, bridgeplates, doorways, and boarding and alighting areas....
-
209.2.2 Bus Loading Zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
T204.2 Doorways with Lifts, Ramps or Bridgeplates
Doorways with lifts or ramps shall comply with T502.2....
-
T302.3 Openings
Ramp and bridgeplate surfaces shall be permitted to have one opening 1½ inches (38 mm) maximum in width and 4½ inches (115 mm) maximum in length to allow the operator to grasp the ramp or...
-
Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
They reported that, in order to avoid extending the ramps a longer distance outside the bus, some 1:6 ramps were designed with a fixed slope inside the bus and a variable slope outside the...
-
209.2.2 Bus Loading Zones
209.2.2 Bus Loading Zones....
-
CHAPTER 4: BOARDING AND ALIGHTING
-
T402 Ramps and Bridgeplates
-
Level boarding
If not using a lift or ramp to provide level boarding, the grantee must submit to FTA a demonstration of equivalent facilitation....
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope....
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
T402.3 Installation and Operation
When used for boarding and alighting, ramps and bridgeplates shall be firmly attached to the non-rail vehicle to prevent displacement....
-
T402.5 Surfaces
Ramp and bridgeplate surface material shall comply with T302 and extend across the full width and length of the ramp or bridgeplate....
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum....
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2....
-
T402.9 Transitions
Vertical surface discontinuities at transitions from boarding and alighting areas to ramps and bridgeplates shall comply with T302.4....
-
T402.10 Visual Contrast
The perimeter of the walking surface on ramps and bridgeplates shall be marked by a stripe....
-
T402.11 Gaps
When ramps or bridgeplates are deployed for boarding and alighting, gaps between the ramp or bridgeplate surface and floor of non-rail vehicles shall not permit passage of a sphere more...
-
T402.12 Stowage
Where portable ramps and bridgeplates are permitted, a compartment, securement system, or other storage method shall be provided within the non-rail vehicle to stow such ramps and bridgeplates...
-
T404 Level Boarding and Alighting
-
T404.3 Ramps and Bridgeplates
platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger load with the vehicle at rest, non-rail vehicles shall provide ramps...
-
E. Chapter 4: Boarding and Alighting
All technical provisions related to boarding and alighting—including level boarding bus systems and steps (which formerly appeared in Chapters 2 and 5 respectively in the proposed rule)—...